PD 1096 - National Building Code of the Philippines (part 1)

Share

Summary

This video, presented by Engineer Joseph Ray Garcia, covers the first half of the Implementing Rules and Regulations (IRR) of the National Building Code of the Philippines, or Presidential Decree (PD) 1096. It details the history of building codes in the Philippines, starting from the lack of a national code before 1972, the enactment of RA 6541, and its subsequent revision by PD 1096 in 1977. The presentation also outlines the reasons for these updates, including technological advancements and the need for more unified regulations. Key aspects of the code are discussed across eleven chapters, including general provisions, administration and enforcement, permit and inspection processes, types of construction, fire zones, fire-resistive requirements, building classification by occupancy, light and ventilation standards, sanitation, building projections over streets, and pedestrian safeguards during construction and demolition. The video emphasizes the importance of these regulations in ensuring public safety, health, and welfare within the built environment, highlighting the responsibilities of various officials and the penalties for non-compliance. Current legislative efforts to update the almost two-decade-old IRR are also mentioned, reflecting the ongoing need to adapt building codes to modern challenges.

Highlights

Introduction to PD 1096 and its Historical Context
00:00:01

Engineer Joseph Ray Garcia presents the first half of the Implementing Rules and Regulations for the National Building Code of the Philippines (PD 1096). This decree, enacted in 1977, sets safety rules for buildings, addressing urbanization and ensuring developers incorporate modern technical knowledge in building design, construction, maintenance, and use. The code updates rules from RA 6541, which was the original law from 1972, making them clearer and more relevant due to technological advancements and changes in laws. Before 1972, there was no comprehensive national building code, leading to inconsistent local regulations. RA 6541 sought to standardize these, and five years later, PD 1096 revised it to address emerging challenges, technological advancements, and building practices, streamlining disparate regulations into a unified code.

Updates to the Implementing Rules and Regulations (IRR) and Legislative Bills
00:05:41

Nearly 30 years after PD 1096, the revised IRR from the Department of Public Works and Highways (DPWH) in 2005 includes additional provisions to align with the original code's chapters. The need to update the existing IRR is critical, as it is nearly two decades old and considered outdated. Legislative bills, such as House Bill 5607 (strengthening PD 1096 with nationwide inspections and stiff penalties), Senate Bill 2087 (ordaining a new building code), and Senate Bill 1239 (establishing the Philippine Building Act of 2019), aim to modernize and strengthen the building code's implementation.

Chapter 1: General Provisions of the National Building Code
00:08:42

Chapter 1, 'General Provisions,' outlines the code's objectives, definitions, and scope. Section 102 declares the government's policy to protect public safety, health, property, and welfare, while considering environmental management. The code sets basic standards for buildings, covering location, design, and construction. Section 103 defines the code's scope, applying to all public and private buildings from design to demolition, with an exception for traditional indigenous family dwellings to respect cultural diversity. Section 104 stresses safety and proper function for all buildings, requiring environmental protection for manufacturing facilities and continuous maintenance. Section 105 dictates site requirements: building sites must be safe, free from hazards, and suitable for the intended use, especially residences. Section 106 covers the definitions of various terms used in the code.

Chapter 2: Administration and Enforcement of the Building Code
00:11:50

This chapter details the administration and enforcement of the building code. Section 201 places the primary responsibility on the Secretary of Public Works and Highways (now DPWH) to enforce rules and penalize violators. Section 202 describes the Technical Staff as qualified professionals in building design and construction. Section 203 outlines the Secretary's powers: developing policies, creating enforcement regulations, approving amendments to referral codes, and determining fees. Section 204 mandates providing professional, technical, and scientific services, including testing laboratories, and allows for inter-agency assistance. Section 205 assigns building officials the responsibility for code implementation, with district, city, or municipal engineers potentially appointed to these roles. Section 206 sets the qualifications for building officials, including being a Filipino citizen, a registered architect or civil engineer, a member of a recognized professional organization for at least two years, and having five years of professional experience. Section 207 details their duties, such as enforcing the code, issuing permits, conducting inspections, issuing stop-work orders, and ordering cessation of occupancy for violations.

Fees, Exemptions, Fines, and Handling Dangerous Buildings
00:16:05

Section 208 concerns fees management, requiring officials to keep records of collected fees, retaining 20% for office expenses and depositing 80% into the treasury. Section 209 exempts public buildings and traditional indigenous family dwellings (owner-occupied, made of native materials, costing less than P50,000) from permit fees. Section 210 allows the Secretary to allocate up to 20% of fee income for office expenses. Section 211 states that the Secretary creates implementing rules, regulations, and standards, which become effective after newspaper publication. Section 212 permits administrative fines of up to P10,000 for code violations. Section 213 imposes severe penalties for illegal violations, including fines up to P20,000, imprisonment up to two years, or both; corporate officials are held responsible, and aliens face deportation. Section 214 defines dangerous buildings as structurally unsafe, lacking safe exits, or posing fire/safety hazards. Section 215 empowers building officials to order repairs, evacuation, or demolition of such buildings, with legal action taken under the Civil Code. Section 216 clarifies that these remedies are supplementary to other existing legal actions.

Chapter 3: Permits and Inspection Processes
00:19:56

Chapter 3 covers permits and inspection. Section 301 requires a building permit for any construction, alteration, or demolition. Section 302 details permit application requirements: a written application with work description, property title, use, occupancy, estimated cost, and five sets of plans sealed by registered engineers. Sections 303 and 304 describe processing and issuance. The building official and staff process applications, ensuring compliance with zoning and safety. Permits are issued within 15 days upon satisfaction and fee payment; partial permits are possible, and plan changes need approval. Section 305 addresses permit validity, stating that permits don't authorize code disregard, and defective plans require corrections. Permits expire after one year if construction doesn't start, or after 120 days of suspension or abandonment. Section 306 allows officials to refuse, suspend, or revoke permits due to errors or non-compliance, requiring written notice.

Appeals, Inspection, and Certificate of Occupancy
00:23:21

Section 307 grants applicants the right to appeal permit non-issuance, suspension, or revocation to the Secretary within 15 days, whose decision is final but reviewable by the Office of the President. Section 308 mandates building owners to hire a licensed architect or civil engineer for full-time inspection and supervision. This professional maintains a logbook of progress, tests, and weather, and submits it with a completion certificate to the building official. Section 309 requires a certificate of occupancy before any building can be used or occupied, or its use changed. This certificate, issued by the building official within 30 days of final inspection and completion submission, confirms code compliance and must be visibly displayed. Procedures for non-issuance, suspension, or revocation follow sections 306 and 307.

Chapter 4: Types of Construction and Requirements
00:25:48

Chapter 4, Section 401, outlines types of construction: Type I (primarily wood), Type II (wood with 1-hour fire-resistant materials), Type III (masonry and wood with 1-hour fire resistance and fire-resistive exterior walls), Type IV (steel, iron, concrete, or masonry with incombustible fire-resistive walls, ceilings, and partitions, allowing treated wood for non-load-bearing interior partitions), and Type V (entirely fire-resistive, with structural elements of steel, iron, concrete, or masonry, and incombustible walls, ceilings, and partitions). Section 402 prohibits changing construction types without meeting the new type's requirements unless the building official approves it as safer. Section 403 details specific standards for each construction type, covering structure, walls, floors, exits, and roofs, to ensure building strength and safety.

Chapter 5: Fire Zones and Regulations
00:28:51

Chapter 5 focuses on fire zones. Section 501 defines fire zones as designated areas for specific building types based on use, construction, and fire resistance. Section 502 states that if a building spans multiple fire zones, the stricter rules apply if more than one-third of its total floor area is in the more restrictive zone. Section 503 requires any building moved into a fire zone to comply with its requirements. Section 504 allows temporary structures (reviewing stands, sheds) in fire zones with special permits, provided they meet safety standards and are removed after permit expiration. Section 505 considers street centerlines as property lines for measurements, perpendicular to the street. Section 506 outlines limitations for existing buildings in fire zones that don't meet new standards: they cannot be enlarged, altered, or moved unless completely demolished, moved to a less restrictive zone, or alterations don't exceed 20% of the building's value and don't increase fire hazard. Additions must be separated by firewalls, and repairs due to disasters are allowed if costs don't exceed 20% of replacement cost. Section 507 mandates the secretary to establish clear rules for fire zones based on local plans and area characteristics.

Chapter 6: Fire-Resistive Requirements
00:33:18

Chapter 6 covers fire-resistive requirements. Section 601 defines 'fire-resistive rating' as a material's fire-withstanding ability, determined by standardized tests. Section 602 specifies 'fire-resistive time period rating' as the duration a material can resist burning, typically measured in hours. Section 603 requires construction materials to be classified based on their fire resistance, determined by accepted testing methods or the Secretary. Section 604 states that the Secretary is responsible for setting standards and regulations for fire safety, including testing procedures for materials, installation of fire doors and windows, and protection of structural elements.

Chapter 7: Building Classification and Occupancy Requirements
00:34:49

Chapter 7 categorizes building uses and occupancies. Group A (residential dwellings), Group B (multiple-person residences like apartments or hotels), Group C (educational/recreational facilities like schools), Group D (institutional buildings, divided into three divisions for mental hospitals, nurseries/hospitals with non-ambulatory patients, and nursing homes for ambulatory patients or children's homes). Group E covers business and mercantile establishments (e.g., gasoline stations, offices, factories), including aircraft hangars without flame work. Group F is for industrial buildings (e.g., ice plants, power plants, cold storage). Group G is for storage and hazardous buildings (e.g., flammable liquids, dry cleaning plants). Group H is for assemblies (assembly halls, stadiums) with fewer than 1,000 occupants, and Group I is for assemblies with 1,000 or more occupants. Group J includes accessory structures (e.g., private garages, fences, towers, tanks).

Occupancy Changes, Mixed Use, and Fire Separation
00:38:28

Section 702 states that changing a building's use requires meeting safety standards for the new use, with approval from the building official if the new use is less risky. Section 703 addresses mixed occupancy buildings, where the strictest safety rules generally apply to the whole building, with exceptions for one-story buildings and minor uses. Occupancy separations (vertical, horizontal, or other forms) are required to safely separate different parts of a building. These separations are classified by their fire resistance (1-hour, 2-hour, 3-hour, and 4-hour), dictating how long they can withstand fire and specific requirements for openings. Fire separation for different occupancies typically requires walls resistant to fire for at least one hour, with supporting structures also being fire-resistant for horizontal separations.

Building Location, Allowable Area, and Height
00:41:31

Section 704 outlines rules for building placement and fire protection. Buildings must connect to a public space, yard, or street on at least one side. Exterior walls need fire-resistant materials and protected openings. Protruding building parts cannot extend beyond a certain distance from the property line, and window openings needing protection due to proximity to property lines cannot exceed half of the wall's area. Buildings on the same property or those with courts are treated with imagined dividing lines for safety, applying stricter rules if multiple buildings are present. Section 705 details allowable floor area, which is limited by the secretary based on building use and construction type; parts separated by standard walls can be considered separate buildings. Section 706 allows for increased floor area if a building is surrounded by public spaces, with building official approval. Section 707 determines maximum building height and number of floors based on occupancy, construction type, population density, street width, and parking needs, with rules for measuring height from the ground.

Minimum Requirements for Group A Dwellings and General Safety
00:44:31

Section 708 focuses on minimum requirements for Group A dwellings, covering location, light, ventilation, sanitation, and foundation strength. Specific requirements include: wooden posts must meet size standards and be anchored; floors must handle set weight loads; roofs must withstand wind pressure; staircases must meet weight, height, and depth standards; every home needs at least one clear exit; and electrical/mechanical systems must adhere to codes. Section 709 covers general requirements for all building types, including construction height and area, placement on property, emergency exits, lighting, ventilation, sanitation, fire safety, and special risk considerations to ensure safety and health for occupants.

Chapter 8: Light and Ventilation Requirements
00:46:30

Chapter 8 outlines light and ventilation requirements. Section 801 mandates buildings to provide sufficient light and ventilation, facing a street or public alley, without altering room size or window area. Enlarging a building must not compromise required court or yard dimensions. Section 802 details site occupancy measurement at ground level, excluding courts, yards, and light wells, with specific exclusions for projections. Section 803 specifies that minimum site occupancy depends on building use, construction, site characteristics, and local zoning. Section 804 covers courts, mandating a minimum horizontal dimension of 2 meters, with inner courts requiring a passageway (at least 1.2m wide) or a door to a street/yard. Section 805 sets ceiling heights: 2.4m for habitable rooms with artificial ventilation, 2.7m for natural ventilation rooms; first stories must be 2.7m high, subsequent stories 2.1m. Mezzanines need 1.8m clear height above and below. Section 806 specifies minimum room dimensions: 6 sq.m. for habitable rooms (min. dimension 2m), 3 sq.m. for kitchens (min. dimension 1.5m), and 1.2 sq.m. for bathrooms/toilets (min. dimension 0.9m).

Airspace, Window Openings, Vent Shafts, and Artificial Ventilation
00:49:56

Section 807 dictates airspace requirements: 3 cubic meters per person and 1 sq.m. floor area for school rooms; 12 cubic meters per person for workshops, factories, and offices; and 14 cubic meters for habitable rooms. Section 808 addresses window openings: rooms without artificial ventilation must have windows totaling at least 10% of the floor area, opening to a courtyard, street, or open water. Section 809 details vent shafts: horizontal cross-sectional area of at least 0.10 sq.m per meter of height, minimum 1 sq.m total area, and smallest dimension not less than 600mm. Skylights over vent shafts must match the maximum required shaft area, and air ducts must connect to a street/court via a horizontal duct of at least 0.3 sq.m and a minimum dimension of 300mm. Section 810 specifies ventilation skylights: glass area as large as replaced windows, with movable sashes or louvers, or effective artificial ventilation. Section 811 covers artificial ventilation: required in industrial/heating rooms to prevent air buildup. Specific air change rates apply: three changes/hour for offices/retail/factories above grade; ten changes/hour for kitchens/boiler rooms; specific air supply per person for assembly rooms and institutional dormitories. The Philippine Mechanical Engineering Code provides provisions for other rooms.

Chapter 9: Sanitation Requirements
00:54:02

Chapter 9 focuses on sanitation. Section 901 emphasizes health and well-being in buildings, including clean water, effective plumbing, wastewater treatment, stormwater drainage, pest control, and noise reduction. Section 902 outlines water supply requirements: potable water from municipal systems or compliant private sources, adhering to PH Water Code regulations. Water piping must follow the National Plumbing Code. Section 903 covers wastewater disposal: sanitary sewage to municipal systems or septic tanks, and industrial wastewater meeting health and environmental criteria. Section 904 mandates separate storm drainage systems to prevent mixing with sewage and ensure proper water accumulation prevention. Section 905 addresses pest control: rot-proofing for hollow/wood construction, pest-proof garbage bins, and screened dining areas. Section 906 requires noise reduction devices in industrial establishments to meet government noise levels. Section 907 mandates that all pipes meet Philippine Standard Council specifications.

Chapter 10: Building Projections Over Streets
00:57:21

Chapter 10 covers building projections over streets. Section 1001 states that no part of a building or its appendages should extend beyond the property line unless permitted. Projections over public property are measured horizontally from the property line. Section 1002 prohibits extensions into alleys or main roads, with exceptions: footings on national roads may extend 300mm if 2.4m below grade, and foundations may encroach sidewalks by 500mm if 600mm below established grade, provided they don't obstruct utilities. Section 1003 specifies that projections over an alley or street must be uniform, adhere to Table 103-A, and maintain a 3-meter clearance between the balcony's lowest part and the street grade. Section 1004 mandates arcades on sidewalks or streets when required by zoning, with uniform width/height and a minimum 3-meter clearance. Section 1005 details canopies (marques) as permanent roof structures: 300mm horizontal clearance from curb line, 3m vertical clearance from pavement/ground. Marques must be fire-resistant, have drainage, and not obstruct standpipe connections or exits. Section 106 states that movable awnings must have a 300mm horizontal clearance from the curb, a 2.4m vertical clearance from the ground, and not obstruct exits when folded. Section 107 prohibits doors/windows less than 2.4m above ground from extending past the property line when open, except for fire exits. Section 108 requires corner buildings or solid fences adjacent to public streets narrower than 3.6m to be truncated at the corner, creating a triangular face perpendicular to the street intersection, unless arcades are present.

Chapter 11: Pedestrian Safeguards During Construction/Demolition
01:02:32

Chapter 11 addresses pedestrian safeguards during construction or demolition. Section 1101 states that building permit work must not obstruct public ways without adhering to regulations, ensuring pedestrian safety. Section 1102 prohibits material and equipment storage on public property that impedes access or obstructs utilities/drainage. Section 1103 bans mixing mortar or concrete on public streets for safety and cleanliness. Section 1104 mandates protecting public and private utilities from construction damage. Section 1105 requires temporary walkways during construction/demolition, with a minimum width of 1.2m, support for 650 kg/sq.m, and a durable surface. Section 1106 prescribes pedestrian protection: railings (1m high, strong) where walkways extend into roadways or are adjacent to excavations; fences (2.4m high, enclosing site) with closed doors; canopies (2.4m clear height) over walkways, with protective measures (curb boards, railings) if materials are stored on top.

Maintenance of Protective Devices and Demolition Regulations
01:05:27

Section 1107 stresses maintaining protective devices (fences, canopies) in good condition for pedestrian safety, to be removed within 30 days after they are no longer needed, as determined by the building official. Section 1108 outlines demolition regulations: all necessary pedestrian protective structures must be in place before demolition begins. The building official can request plans, specifications, and a complete demolition schedule, and work cannot proceed until these documents are approved, ensuring safety and compliance throughout the demolition process.